Overview
The TDVA-360/25 vacuum circuit breaker uses a silicone rubber insulator in a single-break upright design. It is easy to install on roofs and fully interchangeable with air circuit breakers, serving the Shaoshan DC locomotive fleet.
Main technical data
Rated voltage 25 kV, maximum 32 kV, rated current 630 A, rated short-circuit breaking current 12.5 kA, rated breaking capacity 360 MVA, mechanical endurance 200,000 operations.
Features
- Silicone rubber insulator, single-break upright design, simple roof installation.
- Long mechanical and electrical life, high reliability and insulation safety class, low maintenance.
- Fully interchangeable with air circuit breakers, designed to IEC 60077 (GB/T 21413.4-2008).
Service record
In service since 2002 across the Shaoshan DC locomotive families SS3, SS3B, SS4, SS4G, SS6B, SS7, SS7C, SS7E, SS8 and SS9, with more than 8,000 units installed (published figure).
| Model | TDVA-360/25 |
|---|---|
| Construction & insulation | silicone rubber insulator, single-break upright, roof mounting |
| Rated voltage | 25 kV (max. 32 kV) |
| Rated current | 630 A |
| Standards | IEC 60077 / GB/T 21413.4-2008 |
Need a model or overhaul plan?
Send the vehicle type and voltage class, original model or overhaul grade — we reply with a configuration and quotation.