Overview
The TDJ2 integrates a vacuum circuit breaker (silicone rubber insulator) with a manually operated earthing switch in one compact, lightweight unit for roof mounting on 25 kV EMUs, locomotives and metro vehicles.
Main technical data
Vacuum circuit breaker: rated voltage 25 kV, maximum 33 kV, rated current 1000 A, rated short-circuit breaking current 20 kA, rated breaking capacity 660 MVA, mechanical endurance ≥20,000 operations.
Earthing switch: rated voltage 25 kV, maximum 33 kV, rated current 400 A, short-time withstand current 20 kA/1s, mechanical endurance 300,000 operations.
Features
- Integrated vacuum circuit breaker (silicone insulator) plus manual earthing switch — compact and light.
- Easy roof installation, high breaking capacity, long mechanical and electrical life, high reliability.
- High insulation safety class with low maintenance, designed to IEC 60077 (GB/T 21413.4-2008).
Service record
In service since 2015 on Argentina Roca line EMUs, with 86 units installed (published figure).
| Model | TDJ2 |
|---|---|
| Construction & insulation | VCB (silicone insulator) + manual earthing switch, roof mounting |
| Rated voltage | 25 kV (max. 33 kV) |
| Rated current | 1000 A (VCB) / 400 A (earthing switch) |
| Standards | IEC 60077 / GB/T 21413.4-2008 |